What is capacity factor, and can satellite imagery approximate it between EIA filings?

Capacity factor is the ratio of what a plant actually generated over a period to what it could have generated running flat out the whole time. A 600 MW coal unit that averages 400 MW over a month is running at a capacity factor near 67%. It's the single number that tells you whether a unit is baseloading, cycling, or sitting mostly idle, and it drives everything downstream: fuel burn estimates, emissions totals, basis calls on the local hub, and how much headroom a market has before it needs the next marginal unit online.
The problem is timing. EIA Form 923 generation and fuel data comes out with roughly a two-month lag, and even then it gets revised in later releases. Form 860 updates on capacity and status changes run on their own slower cycle. If you're trying to call a fuel-switching trade or flag a derate before the rest of the desk sees it in the official numbers, a two-month-old data point isn't a nowcast, it's a history lesson. Analysts have patched this gap for years with ICE pricing tells, pipeline flow data, and whatever a utility happens to say on an earnings call, none of which is a direct read on a specific plant's output.
Why capacity factor doesn't show up directly in a satellite image
No overhead image gives you megawatt-hours. What it gives you is a set of physical signatures that move with generation, and those signatures are what a capacity-factor proxy has to be built from.
Stack plume presence and persistence track combustion activity. A hot, steady plume across repeated weekly passes reads differently than an intermittent one, and a dark stack across several consecutive visits is a reasonable tell for an outage or a deep derate. Cooling-water signatures, discharge channel temperature and flow where a plant uses once-through or tower cooling, scale with thermal load because cooling demand rises and falls with the heat the unit is rejecting. For coal units specifically, the coal pile itself is a fuel-consumption proxy: a pile that's visibly drawing down week over week implies burn, and a pile that's holding steady or growing implies the unit is running light or idle.
None of these signals is a calibrated capacity factor on its own. Combined and tracked on a weekly cadence against the same named plant, they start to look like a directional activity curve, and that curve is what you chart against the generation and commodity series you already follow.
What a weekly imagery signal is and isn't good for
Treat it as a nowcast, not a replacement for the eventual EIA number. The 923 and 860 filings remain the reconciled, audited record, the thing you'd use for a compliance memo or a final burn calculation. An imagery-derived signal is for the weeks in between, when you need to know whether a plant looks like it's ramping back up after a planned outage, whether a pile drawdown pattern matches what the dispatch curve would predict, or whether a unit that's supposed to be baseloading has gone quiet for three straight passes.
It's also plant-specific in a way that aggregate fuel-burn estimates or regional load data aren't. If you're watching one named facility because of a specific trade thesis, a local outage, or a fuel-supply contract, a weekly stack-and-pile read on that plant tells you something a statewide generation mix figure can't.
The honest caveat: weather, maintenance activity unrelated to output, and cloud cover on a given pass can all muddy any single week's read. That's why the value is in the series, not any one image, the same way nobody trades off a single data point in a fuel-burn series either.
Power Plant Activity builds that weekly series for a named thermal plant, combining stack and cooling-water signatures with coal-pile volumetrics so you have something to chart against generation and commodity data in the weeks before the official filing catches up.
If you're tracking a specific plant between filing windows, it's worth seeing what a weekly nowcast on it looks like.